SEND US AN EMAIL

CONTACT US
HOME
COMPANY PROFILE
PRODUCTS
BLOGS
Dialysis Machine Medcare

Dialysis Machine Medcare

The blood purification equipment with full functions

CVVHDF, CPFA, DFPP, MARS, FPSA, HP and ETC

Full Range Of Blood Purification Equipments

Citrate anti-coagulation and double input channel for substitution fluid flow

 

Clinical advantages of citrate anticoagulation:

  • All treatment modes can adopt the Citrate anti-coagulation.
  • Seperate citrate infusion pump and weighing scale.
  • Control the citrate flow accurately. Automatic injection by proportion, achieve the safe topical citrate anticoagulation.

Advantage of double input channel for substitution fluid flow:

  • Avoid Calcium ion precipitation, ensure the treatment result.
  • Automatic injection by proportion, achieve the safety supplement of the substitution fluid.
  • E x ternal infusion pump is not required, easy operation and safe treatment.

Flexibility

Convenient one-button prime

 

One button mode switch and one button prime, more convenient for clinical treatment.

 

Multiple dilution modes of  substitution fluid

Adopt various methods for substitution fluid such as the pre-dilution, post- dilution, pre -post mix dilution. One button switch dilution method, do not need to change the connection of tubing manually.

 

Multi-functional infusion pump

The multi-functional infusion pump can be used for bolus injection of heparin, calcium chloride and ect. and recognize the syringe size automatically, such as 10ml,20ml,30ml and 50ml.

 

Safety Movement 

Small blind field of vision to ensure safety of  equipment  movement. 0 parts failure for 120KM movement test.

Easy operation for tubing installation, the system will guide installation with pictures and text.

 

Ergonomic design, make the machines serve people

Rotatable  big touch screen operation system, to observe and operate from different angles, to meet the requirement for  rapid response under  different scenarios.

 

Reliable fluid change management of substitution fluid and waste fluid 

The maximum range of weighing scale is 30kg, and can hang different fluid bags with higher accuracy of fluid meter, which can decrease the workload of medical care.Unique design for foolproof fluid change, easy operation, high safety.

 

Precise

The temperature of substitution fluid flow can be detected, the temperature control is more accurate.

The liquid temperature is detected and feedback control precisely:

  • Unique substitution fluid flow temperature monitor and feedback system.
  • Adopt infrared monitor to detect the temperature, the accuracy can be ±1.
  • Adopt double-side heating device which can support large flow heating.

Precise control of fluid balance:

  • The scale system accuracy can be ±5g.
  • The fluid balance error can not be more than ±20mL/h, the Cumulative error can not be more than±100mL.
  • Satisfy the clinical requirement  for  the fluid accuracy
  • (1mL/min~250mL/min).

More Accurate Liquid Flow:

  • Five high-precision peristaltic pumps.
  • Wide flow range for meet  more clinical needs.
  • Stable  operation and more comfortable treatment.
  • Stable  operation and more comfortable treatment.

Reliable parts :

  • Motors, weighing sensors and pressure sensors have been purchased globally , ensure the quality of the products.
  • The peristaltic pump is executed according to the strict quality standards and have been passed the trouble-free test of continuous operation for  90 million revolutions.

Technical Parameter:

Basic Information

 

DimensionHeight 1720 mm/Width 635 mm/Thickness 578 mm
WeightAbout 75Kg
Electrical Parameters
Voltage~110/220V
Frequency50/60Hz
Power500VA
Backup Battery 2x12V/4Ah
Pressure Monitoring Venous Pressure 
Venous Pressure Monitoring(Vp)-500mmHg ~ +700mmHg Accuracy:±5mmHg
Arterial Pressure Monitoring(Ap)-500mmHg – +700mmHg Accuracy:±5mmHg
Transmembrane Pressure Monitoring(Tmp)-500mmHg ~ +700mmHg  Accuracy:±5mmHg
Primary Membrane External Pressure Monitoring (Pm1)-500mmHg ~ +700mmHg Accuracy:±5mmHg
Secondary Membrane Pressure Monitoring(Pm2)-500mmHg ~ +700mmHg  Accuracy:±5mmHg
Liquid Balance Control
Scale Number4
Rehydration Scale0kg ~ 30kg Accuracy: ±5g or ±0.1%
Waste Liquid Scale0kg~30kg Accuracy: ±5g or ±0.1%
Auxiliary Rehydration Scale I0kg ~ 12kg Accuracy: ±5g or ±0.1%
~ Scale I0kg ~ 12kgAccuracy: ±5g or ±0.1%